18ga Flush Steel Door

The Easiest Way to Order Up to 90 Min. Fire Rated Metal Doors

  • Z
    Contractor Pricing & Project Based Discounts
  • Z
    Quick Quotes & Fast Lead Times
  • Z
    In Stock & Custom Doors and Frames
  • Z
    Expert Support & Jobsite Delivery
  • N
    A solution specialist will help you find the right products

Free Nationwide Shipping

Nearly all orders ship free

Contractor Pricing & Project Discounts

Low prices on commercial door products

One on One Dedicated Support

Work with your commercial door specialist

Up to 90 Min. Fire Rated Metal Doors

Shop in stock and custom 90 min fire rated metal doors

18ga. Galvannealed Steel Commercial Flush Door

  • Interior or Exterior Use
  • Fire Rated from 0-180 Min.
  • Single or Double Door (Pairs)
  • In Stock & Custom Options

18ga. Galvannealed Steel Embossed 2-Panel Commercial Door

  • Interior or Exterior Use
  • Fire Rated from 0-180 Min.
  • Single or Double Door (Pairs)
  • In Stock & Custom Options

18ga. Galvannealed Steel Embossed 6-Panel Commercial Door

  • Interior or Exterior Use
  • Fire Rated from 0-180 Min.
  • Single or Double Door (Pairs)
  • In Stock & Custom Options
18ga. Galvannealed Steel Commercial Door with Polystyrene Core

18ga. Galvannealed Steel Commercial Door with 12” x 12” Vision Lite and Safety Wire Glass

  • Interior or Exterior Use
  • Fire Rated from 0 – 90 Min.
  • Security Wire Glass
  • In Stock & Custom Options
18ga Galvannealed Steel Commercial Door with Polystyrene Core 7 x 22

18ga. Galvannealed Steel Commercial Door with 7” x 22” Vision Lite and Safety Wire Glass

  • Interior or Exterior Use
  • Fire Rated from 0 – 90 Min.
  • Security Wire Glass
  • In Stock & Custom Options
18ga Galvannealed Steel Commercial Door with Polystyrene Core 6 x 27

18ga. Galvannealed Steel Commercial Door with 6” x 27” Vision Lite and Safety Wire Glass

  • Interior or Exterior Use
  • Fire Rated from 0 – 90 Min.
  • Security Wire Glass
  • In Stock & Custom Options
18ga Galvannealed Steel Commercial Door with Polystyrene Core 5 x 35

18ga. Galvannealed Steel Commercial Door with 5” x 35” Vision Lite and Safety Wire Glass

  • Interior or Exterior Use
  • Fire Rated from 0 – 90 Min.
  • Security Wire Glass
  • In Stock & Custom Options

18ga. Galvannealed Steel Commercial Door with 12” x 12” Vision Lite and Fire Rated Glass Ceramic

  • Interior or Exterior Use
  • Fire Rated from 0-180 Min.
  • Single or Double Door (Pairs)
  • In Stock & Custom Options

18ga. Galvannealed Steel Commercial Door with 7” x 22” Vision Lite and Fire Rated Glass Ceramic

  • Interior or Exterior Use
  • Fire Rated from 0-180 Min.
  • Single or Double Door (Pairs)
  • In Stock & Custom Options

18ga. Galvannealed Steel Commercial Door with 6” x 27” Vision Lite and Fire Rated Glass Ceramic

  • Interior or Exterior Use
  • Fire Rated from 0-180 Min.
  • Single or Double Door (Pairs)
  • In Stock & Custom Options
Metal Door With 5 x 35 Fire Rated Glass

18ga. Galvannealed Steel Commercial Door with 5” x 35” Vision Lite and Fire Rated Glass Ceramic

  • Interior or Exterior Use
  • Fire Rated from 0-180 Min.
  • Single or Double Door (Pairs)
  • In Stock & Custom Options

18ga. Galvannealed Steel Commercial Door with Half Vision Lite and Fire Rated Glass Ceramic

  • Interior or Exterior Use
  • Fire Rated from 0-90 Min.
  • Single or Double Door (Pairs)
  • In Stock & Custom Options

Product Selection Guides

Learn more about Up to 90 Min. Fire Rated Metal Doors

Elevations

F - Flush Door
F – Flush Door

V - Vision Lite Door
V – Vision Lite Door

N - Narrow Lite Glass Door
N – Narrow Lite Glass Door

G - Half Glass Door
G – Half Glass Door

FG - Full Glass Door
FG – Full Glass Door

GG - Glass Above Glass 2-Lite Door
GG – Glass Above Glass 2-Lite Door

E1 - Embossed 1 Panel Door
E1 – Embossed 1 Panel Door

E2 - Embossed 2 Panel Door
E2 – Embossed 2 Panel Door

E6 - Embossed 6 Panel Door
E6 – Embossed 6 Panel Door

L - Louver Door Top or Bottom
L – Louver Door Top or Bottom

Looking for something different? We offer custom configurations for vision lite and louver cutouts. Contact our team today to request your quote.

Surface Material

SDI Hollow Metal Door Levels


SDI Level 1 – Standard Duty
Designed for light-duty commercial applications with relatively low traffic and minimal abuse. Level 1 doors are typically 20-gauge (0.032 in. minimum) steel and are commonly used for interior openings such as offices, closets, and similar low-use areas.

SDI Level 2 – Heavy Duty
Designed for typical commercial applications that experience moderate traffic and regular use. Level 2 doors are typically 18-gauge (0.042 in. minimum) steel and are commonly specified for offices, retail spaces, multifamily common areas, and general commercial buildings.

SDI Level 3 – Extra Heavy Duty
Designed for high-traffic openings and applications requiring greater durability and resistance to physical abuse. Level 3 doors are typically 16-gauge (0.053 in. minimum) steel and are frequently used in schools, hospitals, industrial facilities, public buildings, and other demanding environments.

SDI Level 4 – Maximum Duty
The most robust SDI construction level, intended for openings exposed to very high traffic, severe use, or abuse. Level 4 doors are typically 14-gauge (0.067 in. minimum) steel and are commonly used in detention, industrial, institutional, and other high-abuse applications.

Hollow Metal Door Materials


Cold-Rolled Steel (CRS)
Cold-rolled steel is smooth, uncoated sheet steel commonly used for interior up to 90 min. fire rated metal doors and frames. It provides an excellent surface for painting but has less corrosion resistance than galvanized or galvannealed steel, making it best suited for dry, climate-controlled environments.

Galvanized Steel
Galvanized steel is coated with zinc to provide increased protection against rust and corrosion. It is well suited for exterior openings, humid environments, and other locations where moisture exposure is a concern. Its zinc-rich surface typically requires appropriate preparation before field painting.

Galvannealed Steel
Galvannealed steel receives a zinc coating that is heat-treated to create a zinc-iron alloy at the surface. It combines excellent corrosion resistance with a surface that is particularly well suited for painting, making it a popular choice for both interior and exterior commercial up to 90 min. fire rated metal doors and frames.

Core Types

honeycomb
Honeycomb

polystyrene
Polystyrene

steel stiffened
Steel Stiffened

polyurethane
Polyurethane

Temperature Rise
Temperature Rise

Additional Core Types:
Lead-Lined Core: A specialty hollow metal door construction incorporating lead sheeting within the door to provide radiation shielding.
Ballistic: A reinforced core designed to provide protection against bullets and ballistic threats.
STC: A specially engineered sound-control core that reduces noise transmission through the door.

Size Chart

6'8" Height
Door Call Size Nominal Width Nominal Height
2068 2'0" (24 inch) 6'8" (80 inch)
2468 2'4" (28 inch) 6'8" (80 inch)
2668 2'6" (30 inch) 6'8" (80 inch)
2868 2'8" (32 inch) 6'8" (80 inch)
21068 2'10" (34 inch) 6'8" (80 inch)
3468 3'4" (40 inch) 6'8" (80 inch)
3668 3'6" (42 inch) 6'8" (80 inch)
3868 3'8" (44 inch) 6'8" (80 inch)
4068 4'0" (48 inch) 6'8" (80 inch)
7'0" Height
Door Call Size Nominal Width Nominal Height
2070 2'0" (24 inch) 7'0" (84 inch)
2470 2'4" (28 inch) 7'0" (84 inch)
2670 2'6" (30 inch) 7'0" (84 inch)
2870 2'8" (32 inch) 7'0" (84 inch)
21070 2'10" (34 inch) 7'0" (84 inch)
3470 3'4" (40 inch) 7'0" (84 inch)
3670 3'6" (42 inch) 7'0" (84 inch)
3870 3'8" (44 inch) 7'0" (84 inch)
4070 4'0" (48 inch) 7'0" (84 inch)
8'0" Height
Door Call Size Nominal Width Nominal Height
2080 2'0" (24 inch) 8'0" (96 inch)
2480 2'4" (28 inch) 8'0" (96 inch)
2680 2'6" (30 inch) 8'0" (96 inch)
2880 2'8" (32 inch) 8'0" (96 inch)
21080 2'10" (34 inch) 8'0" (96 inch)
3480 3'4" (40 inch) 8'0" (96 inch)
3680 3'6" (42 inch) 8'0" (96 inch)
3880 3'8" (44 inch) 8'0" (96 inch)
4080 4'0" (48 inch) 8'0" (96 inch)

Configurations

Single Door
Single Door

Double Door Active/Inactive
Double Door Active/Inactive
Secondary Door Can Open When Flush Bolts Are Disengaged

Double Exit Door
Double Exit Door
Both Doors Active w/ SVR Panic

Double Door Push/Pull
Double Door Push/Pull
Both Doors Active
(Cannot Be Fire Rated)

Communicating Door
Communicating Door
For Adjoining Hotel Rooms

Double Egress Door
Double Egress Door
For Emergency Exit In Either Direction

Double Acting Door
Double Acting Door
Swings Both Directions (Cannot Be Fire Rated)

Lock Prep

161 Lock Prep / Deadbolt Prep
161 Lock Prep / Deadbolt Prep
Bored @ 2-3/4″ Backset (ANSI / SDI A115.2)

86 Edge Prep
86 Edge Prep
Mortise Lock Edge Prep w/ Blank Face (ANSI / SDI A115.1)

RPD - Rim Panic Reinforced
RPD – Rim Panic Reinforced
(Blank Edge & Blank Face) Designed for use with panic bar exit devices.

Custom Lock Prep
Custom Lock Prep
(Template Required)

Measuring Instructions

Your Quote is Minutes Away

Get Your Commercial Door and Hardware Quote Now

Real Customers, Real Reviews

Trusted by developers, contractors and organizations throughout the US

Google Reviews

4.8 / 5   5 Star Google Reviews
350+ Google Reviews

Frequently Asked Questions

Why choose USA Fire Door for Up to 90 Min. Fire Rated Metal Doors?

USA Fire Door makes it easy to order the right 90 min. fire rated metal doors for your project. Send us whatever information you have, whether that’s plans and specifications, measurements, photos, an existing door schedule or simply a description of what you’re trying to accomplish. Our solutions specialists will evaluate your requirements and guide you toward products that meet your needs for performance, function, price and lead time.

Don’t know exactly what you need? You don’t have to figure it out on your own. We can identify the information needed to move your project forward and walk you through the steps to collect it. That may include field measurements, product selection, hardware coordination or installation questions. Our team can stay involved as those details are worked out.

90 min. fire rated metal doors can be configured for many commercial openings that require a listed fire door assembly. We can help you work through the required fire rating, opening size, frame, hardware, glazing and other details that must be coordinated for the opening. We focus on the requirements that matter to the project so you can avoid unnecessary options without overlooking important ones.

USA Fire Door can supply 90 min. fire rated metal doors individually or coordinate them with frames and commercial door hardware when the project requires a complete opening. Whether you have a well-developed specification or only a few details from the field, our goal is to remove the guesswork and guide the project to the finish line.

How do I get a quote?

We provide advanced level support right from the beginning. You will be connected with a dedicated solutions specialist who will assist you through all phases of your order process.

3 Ways To Get Started

1. Call +1 (844) 321-3667 to get started ASAP

2. Share project details and request a quote online

3. Have a dedicated solutions specialist contact you directly. Send us a message

Where are 90 min. fire rated metal doors typically used?

90 min. fire rated metal doors are used where the building design calls for a 90-minute fire-protection-rated door assembly and the selected door construction is listed for that application. Typical locations can include corridors, stair enclosures, shafts, mechanical rooms, tenant separations, and other rated barriers, but the exact requirement comes from the wall or barrier rating and the adopted code. The door rating should be confirmed from the project documents rather than selected solely from the room name.

What wall rating is commonly associated with a 90-minute door?

A 90-minute door is commonly paired with certain rated wall or barrier conditions, but the relationship is not a simple one-size-fits-all rule. Opening protectives are assigned ratings based on the type and rating of the wall assembly and the applicable code table. Existing conditions, corridor provisions, shafts, fire barriers, smoke barriers, and local amendments can change the requirement. For ordering, use the rating shown on the door schedule or confirm it with the design professional or authority having jurisdiction.

Do 90 min. fire rated metal doors need a labeled frame and fire-rated hardware?

A fire-rated opening is evaluated as an assembly, not as a door leaf by itself. The frame must be appropriate for the required rating, and hardware used on the opening must be listed or otherwise permitted for the application. Depending on the opening, that may include listed hinges, latching hardware, closers, exit devices, coordinators, gasketing, and other components. The exact requirements vary with the rating, door configuration, occupancy, and listing, so the safest approach is to coordinate the complete opening before ordering.

Can 90 min. fire rated metal doors have glass?

Yes, many 90 min. fire rated metal doors can include listed fire-protection or fire-resistance-rated glazing, but the allowable glass type, exposed area, lite dimensions, and location depend on the door rating and the applicable listings. A standard tempered-glass lite used in a non-rated door cannot simply be substituted into a fire-rated opening. When glass is required, specify the desired vision-lite size and rating early so the door, glazing frame, glass, and label can be supplied as a compatible configuration.

Can 90 min. fire rated metal doors have louvers?

Some 90 min. fire rated metal doors can be supplied with listed fusible-link louvers, but fire-rated louver applications are restricted. The allowable rating, louver size, location, door type, and interaction with glass or exit hardware are controlled by the product listings and code requirements. Certain fire-door configurations do not permit louvers at all. If ventilation is required through a rated opening, identify that requirement before the door is ordered so the proposed louver can be checked against the complete assembly.

Can 90 min. fire rated metal doors be used in pairs?

Yes, many 90 min. fire rated metal doors are available as pairs, but paired fire doors require more coordination than two single leaves placed side by side. Meeting-stile construction, astragals, coordinators, flush bolts, exit devices, latching, closers, and any required gasketing must match the listed configuration. Some hardware arrangements are not available at every rating or door size. For pairs, submit the full opening width, handing or active leaf, hardware set, and required rating with the quote request.

Can I replace only the door leaf in a 90-minute fire-rated opening?

Sometimes, but the replacement leaf has to be compatible with the existing frame, hardware, rating, and opening configuration. Record the labels on the existing door and frame, the exact leaf dimensions, hinge and lock locations, handing, undercut, and hardware before ordering. A new labeled door does not automatically make an older opening compliant if the frame, hardware, field modifications, or installation conditions do not meet the requirements of the assembly. Replacement work should be evaluated as an opening, not just a slab.

What hardware can be used on 90 min. fire rated metal doors?

The hardware depends on the opening function and listing, but fire-rated doors commonly use listed hinges or pivots, positive-latching locksets or exit devices, and self-closing or automatic-closing hardware where required. Pairs can add coordinators, flush bolts, or specific exit-device arrangements. Electrified hardware, continuous hinges, concealed closers, and access-control components may also be possible when the door and frame are properly prepared. Hardware should be selected before fabrication so reinforcements, machining, and labels remain coordinated.

Are custom sizes available for 90 min. fire rated metal doors?

Yes, custom sizes are available for many 90 min. fire rated metal doors, but maximum width, height, pair dimensions, lite sizes, hardware preparations, and construction vary by manufacturer and rating. A door that is available in a large non-rated size may have a smaller maximum size once a fire label is required. For oversized or unusual openings, confirm the dimensions, frame, rating, hardware, and glazing requirements before finalizing the design or ordering replacement material.

What affects the price of 90 min. fire rated metal doors?

The cost of 90 min. fire rated metal doors depends on the door material, rating, size, frame, hardware, glazing or louver requirements, pair configuration, machining, finish, and freight. Higher ratings or specialty configurations can narrow the available constructions and increase cost, but the rating alone is not the whole price. For a useful quote, provide the required rating together with the opening dimensions, frame or wall information, hardware set, and any glass, louver, or access-control requirements so the complete assembly can be priced on the same basis.